Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38447197

RESUMO

OBJECTIVES: To investigate if there is still a place for bioprosthetic mitral valve replacement in children by comparing the prosthetic durability and transplant-free survival after bioprosthetic and mechanical mitral valve replacement. METHODS: We reviewed all mitral valve replacements in children between 1981 and 2020. Bioprosthetic mitral valve replacement cases were individually matched to mechanical mitral valve replacement cases. The incidence rate of a 2nd replacement was calculated using the cumulative incidence function that considered death or transplantation as a competing risk. RESULTS: The median age at implantation was 3.6 years (interquartile range 0.8-7.9) for the bioprosthetic valve cohort (n = 28) and 3 years (interquartile range 1.3-7.8) for the mechanical valve cohort (n = 28). Seven years after bioprosthetic mitral valve replacement, the cumulative incidence of death or transplantation was 17.9% [95% confidence interval (CI) 6.3-34.1] and the cumulative incidence of a 2nd replacement was 63.6% (95% CI 39.9-80.1). Seven years after mechanical mitral valve replacement, the cumulative incidence of death or transplantation was 28.6% (95% CI 13.3-46) and the cumulative incidence of a 2nd replacement was 10.7% (95% CI 2.6-25.5). Fifteen years after mechanical mitral valve replacement, the cumulative incidence of death or transplantation was 33.6% (95% CI 16.2-52.1) and the cumulative incidence of a 2nd replacement was 41.1% (95% CI 18.4-62.7). The cumulative incidence curves for bioprosthetic and mechanical mitral valve replacement were statistically different for a 2nd valve replacement (P < 0.001) but not for death or transplantation (P = 0.33). CONCLUSIONS: There is no difference in transplant-free survival after bioprosthetic and mechanical mitral valve replacement in children. The lifespan of bioprosthetic mitral valves remains limited in children because of structural valve failure due to calcification. After 15 years, 40% of mechanical valves were replaced, primarily because of patient-prosthesis mismatch related to somatic growth.

2.
Cardiol Young ; 34(3): 588-596, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37641941

RESUMO

BACKGROUND: Limited data exist on how trainees in paediatric cardiology are assessed among countries affiliated with the Association of European Paediatric and Congenital Cardiology. METHODS: A structured and approved questionnaire was circulated to educationalists/trainers in 95 Association for European Paediatric and Congenital Cardiology training centres. RESULTS: Trainers from 46 centres responded with complete data in 41 centres. Instructional design included bedside teaching (41/41), didactic teaching (38/41), problem-based learning (28/41), cardiac catheterisation calculations (34/41), journal club (31/41), fellows presenting in the multidisciplinary meeting (41/41), fellows reporting on echocardiograms (34/41), clinical simulation (17/41), echocardiography simulation (10/41), and catheterisation simulation (3/41). Assessment included case-based discussion (n = 27), mini-clinical evaluation exercise (mini-CEX) (n = 12), directly observed procedures (n = 12), oral examination (n = 16), long cases (n = 11), written essay questions (n = 6), multiple choice questions (n = 5), and objective structured clinical examination (n = 2). Entrustable professional activities were utilised in 10 (24%) centres. Feedback was summative only in 17/41 (41%) centres, formative only in 12/41 (29%) centres and a combination of formative and summative feedback in 10/41 (24%) centres. Written feedback was provided in 10/41 (24%) centres. Verbal feedback was most common in 37/41 (90 %) centres. CONCLUSION: There is a marked variation in instructional design and assessment across European paediatric cardiac centres. A wide mix of assessment tools are used. Feedback is provided by the majority of centres, mostly verbal summative feedback. Adopting a programmatic assessment focusing on competency/capability using multiple assessment tools with regular formative multisource feedback may promote assessment for learning of paediatric cardiology trainees.


Assuntos
Cardiologia , Aprendizagem , Humanos , Criança , Cateterismo Cardíaco , Simulação por Computador , Ecocardiografia
3.
Open Heart ; 10(2)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38097363

RESUMO

OBJECTIVES: This study aimed to determine the status of training of adult congenital heart disease (ACHD) cardiologists in Europe. METHODS: A questionnaire was sent to ACHD cardiologists from 34 European countries. RESULTS: Representatives from 31 of 34 countries (91%) responded. ACHD cardiology was recognised by the respective ministry of Health in two countries (7%) as a subspecialty. Two countries (7%) have formally recognised ACHD training programmes, 15 (48%) have informal (neither accredited nor certified) training and 14 (45%) have very limited or no programme. Twenty-five countries (81%) described training ACHD doctors 'on the job'. The median number of ACHD centres per country was 4 (range 0-28), median number of ACHD surgical centres was 3 (0-26) and the median number of ACHD training centres was 2 (range 0-28). An established exit examination in ACHD was conducted in only one country (3%) and formal certification provided by two countries (7%). ACHD cardiologist number versus gross domestic product Pearson correlation coefficient=0.789 (p<0.001). CONCLUSION: Formal or accredited training in ACHD is rare among European countries. Many countries have very limited or no training and resort to 'train people on the job'. Few countries provide either an exit examination or certification. Efforts to harmonise training and establish standards in exit examination and certification may improve training and consequently promote the alignment of high-quality patient care.


Assuntos
Cardiologistas , Cardiologia , Cardiopatias Congênitas , Humanos , Adulto , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Cardiologia/educação , Qualidade da Assistência à Saúde , Europa (Continente)/epidemiologia
4.
ACS Biomater Sci Eng ; 9(11): 5953-5967, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37856240

RESUMO

New horizons in cardiovascular research are opened by using 3D printing for biodegradable implants. This additive manufacturing approach allows the design and fabrication of complex structures according to the patient's imaging data in an accurate, reproducible, cost-effective, and quick manner. Acellular cardiovascular implants produced from biodegradable materials have the potential to provide enough support for in situ tissue regeneration while gradually being replaced by neo-autologous tissue. Subsequently, they have the potential to prevent long-term complications. In this Review, we discuss the current status of 3D printing applications in the development of biodegradable cardiovascular implants with a focus on design, biomaterial selection, fabrication methods, and advantages of implantable controlled release systems. Moreover, we delve into the intricate challenges that accompany the clinical translation of these groundbreaking innovations, presenting a glimpse of potential solutions poised to enable the realization of these technologies in the realm of cardiovascular medicine.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis , Humanos , Preparações de Ação Retardada , Impressão Tridimensional
5.
Pediatr Rep ; 15(2): 301-310, 2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37218926

RESUMO

Idiopathic pulmonary arterial hypertension (IPAH) is an uncommon and severe disease. We report the case of a 7-year-old boy investigated for cardiac murmur and exercise intolerance. Pulmonary hypertension (PH) was suspected at clinical examination and confirmed by echocardiography and cardiac catheterization. This case of pulmonary hypertension was classified as idiopathic given the negative etiological investigation. Vasoreactive testing with oxygen and nitric oxide was negative. Therefore, treatment with sildenafil (1.4 mg/kg/d) and bosentan (3 mg/kg/d) was initiated. This allowed the stabilization of, but not a decrease in, pulmonary artery pressure for the next 5 years, during which the patient's quality of life was significantly reduced. At a later follow-up, the estimated pulmonary pressure was found to have increased and become supra-systemic, with a consequent deterioration in the child's condition. This led to the decision to enter him into a clinical trial that is still ongoing. Idiopathic pulmonary arterial hypertension is a severe disease that can present with non-specific symptoms, such as asthenia and exercise limitation, which are important not to trivialize. The disease is associated with significantly decreased quality of life in affected children and carries a high burden in terms of mortality and morbidity. The current knowledge about IPAH in children is reviewed, with a particular focus on the future prospects for its treatment and the related quality of life of patients.

6.
Am Heart J ; 261: 21-34, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36934977

RESUMO

IMPORTANCE: The use of 18F-FDG PET/CT in diagnostic algorithms for PVE has increased since publication of studies and guidelines advocating its use. The assessment of test accuracy has been limited by small study sizes. We undertook a systematic review using individual patient data (IPD) meta-analysis techniques. OBJECTIVE: To estimate the summary sensitivity and specificity of 18F-FDG PET/CT in diagnosing PVE. We also assessed the effect of patient factors on test accuracy as defined by changes in the odds ratios associated with each factor. The effect of the PET/CT study on the final diagnosis was also assessed when compared to the preliminary Duke classification to determine in which patient group 18F-FDG PET/CT had the greatest utility. STUDY SELECTION: Studies were included if PET/CT was performed for suspicion of PVE and IPD of both the PET/CT result and final diagnosis defined by a gold-standard assessment was available. There were 3 possible final diagnoses ("definite PVE," "possible PVE," and "rejected PVE"). RESULTS: Seventeen studies were included with IPD available for 537 patients (from 538 scans). The summary sensitivity and specificity were 85% (95% CI 74.2%-91.8%) and 86.5% (95% CI 75.8%-92.9%) respectively when patients with final diagnosis of "possible PVE" were classified as positive for PVE. When this group was classified as negative for PVE, sensitivity was 87.4% (95% CI 80.4%-92.1%) and specificity was 84.9% (95% CI 71.5%-92.6%). Patients with a known pathogen (especially coagulase negative staphylococcal species), elevated CRP, a biological or aortic valve infection appeared more likely to have an accurate PET/CT diagnosis. Those with a mechanical valve, prior antibiotic treatment or a transcatheter aortic valve replacement valve were less likely to have an accurate test. Time since valve implantation and the presence of surgical adhesive did not appear to affect test accuracy. Of the patients with a preliminary Duke classification of "possible PVE," 84% received a more conclusive final diagnosis of "definite" or "rejected" PVE after the PET/CT study. CONCLUSIONS AND RELEVANCE: 18F-FDG PET/CT has high sensitivity and specificity in diagnosing PVE and the diagnostic utility is greatest in patients with a preliminary Duke classification of "possible PVE." Some patient factors appear to affect test accuracy, though these results should be interpreted with caution given low patient numbers for subgroup analyses.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18/farmacologia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/diagnóstico , Sensibilidade e Especificidade , Compostos Radiofarmacêuticos/farmacologia
7.
Sci Rep ; 13(1): 4662, 2023 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-36949216

RESUMO

Small diameter vascular grafts (SDVGs) are associated with a high failure rate due to poor endothelialization. The incorporation of a nitric oxide (NO) releasing system improves biocompatibility by using the NO effect to promote endothelial cell (EC) migration and proliferation while preventing bacterial infection. To circumvent the instability of NO donors and to prolong NO releasing, S-nitroso-N-acetyl-D-penicillamine (SNAP) as a NO donor was loaded in multi-walled carbon nanotubes (MWCNTs). Successful loading was confirmed with a maximum SNAP amount of ~ 5% (w/w) by TEM, CHNS analysis and FTIR spectra. SDVGs were 3D printed from polycaprolactone (PCL) and coated with a 1:1 ratio of polyethylene glycol and PCL dopped with different concentrations of SNAP-loaded matrix and combinations of MWCNTs-OH. Coating with 10% (w/w) SNAP-matrix-10% (w/w) SNAP-MWCNT-OH showed a diminished burst release and 18 days of NO release in the range of 0.5-4 × 10-10 mol cm-2 min-1 similar to the NO release from healthy endothelium. NO-releasing SDVGs were cytocompatible, significantly enhanced EC proliferation and migration and diminished bacterial viability. The newly developed SNAP-loaded MWCNT-OH has a great potential to develop NO releasing biomaterials with a prolonged, controlled NO release promoting in-situ endothelialization and tissue integration in vivo, even as an approach towards personalized medicine.


Assuntos
Nanotubos de Carbono , Óxido Nítrico , Óxido Nítrico/metabolismo , S-Nitroso-N-Acetilpenicilamina/farmacologia , Preparações de Ação Retardada , Doadores de Óxido Nítrico/farmacologia , Impressão Tridimensional
8.
Front Pediatr ; 10: 1059894, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36545672
9.
Catheter Cardiovasc Interv ; 100(6): 1059-1066, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36321584

RESUMO

BACKGROUND: Mechanical factors may cause bottlenecks in a Fontan circuit. Extracardiac conduits (ECC) are placed at a young age, but the materials do not allow growth. Restriction in ECC dimensions may deteriorate the function of the circuit. AIMS: This study aimed to evaluate the feasibility and safety of stent expansion of an ECC to the nominal dimension at the time of implant and, if possible, beyond nominal. METHODS: Retrospective, single-center observational review of all ECC Fontan patients who received a stent to expand a previously placed surgical conduit. RESULTS: A total of 44 restrictive conduits were stented over a 14-year study period with a median of 11.8 (interquartile ranges [IQR]: 9.1-13.8) years after ECC placement. Cross-sectional areas were a median of 30% (IQR: 21-42) smaller than the originally placed ECC; there was no gradient in 23/44 patients and in 21/44, a minimal gradient of 1.3 ± 0.5 (range 1-3 mmHg). All conduits could be enlarged with a significant (p < 0.0001) increase in diameter from 13.6 ± 1.8 to 19.2 ± 1.2 mm, corresponding to a median cross-sectional area increase of 171% (IQR: 153-220). In three patients where the conduits were not contracted, expansion of between 127% and 165% was obtained. There were no conduit ruptures and only one minor complication. CONCLUSIONS: ECC in some Fontan patients become smaller than nominal over time, usually without overt symptoms. The dimensions of ECC's can be safely and significantly increased to nominal or even beyond employing stenting. It allows adjustment of ECC dimensions to compensate for somatic growth.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Humanos , Técnica de Fontan/efeitos adversos , Técnica de Fontan/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento
11.
Front Bioeng Biotechnol ; 10: 873453, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35694223

RESUMO

Smart materials are able to react to different stimuli and adapt their shape to the environment. Although the development of 3D printing technology increased the reproducibility and accuracy of scaffold fabrication, 3D printed scaffolds can still be further improved to resemble the native anatomy. 4D printing is an innovative fabrication approach combining 3D printing and smart materials, also known as stimuli-responsive materials. Especially for cardiovascular implants, 4D printing can promisingly create programmable, adaptable prostheses, which facilitates implantation and/or create the topology of the target tissue post implantation. In this review, the principles of 4D printing with a focus on the applied stimuli are explained and the underlying 3D printing technologies are presented. Then, according to the type of stimulus, recent applications of 4D printing in constructing smart cardiovascular implants and future perspectives are discussed.

12.
Cardiol Young ; 32(12): 1966-1983, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35227341

RESUMO

BACKGROUND: Limited data exist on training of European paediatric and adult congenital cardiologists. METHODS: A structured and approved questionnaire was circulated to national delegates of Association for European Paediatric and Congenital Cardiology in 33 European countries. RESULTS: Delegates from 30 countries (91%) responded. Paediatric cardiology was not recognised as a distinct speciality by the respective ministry of Health in seven countries (23%). Twenty countries (67%) have formally accredited paediatric cardiology training programmes, seven (23%) have substantial informal (not accredited or certified) training, and three (10%) have very limited or no programme. Twenty-two countries have a curriculum. Twelve countries have a national training director. There was one paediatric cardiology centre per 2.66 million population (range 0.87-9.64 million), one cardiac surgical centre per 4.73 million population (range 1.63-10.72 million), and one training centre per 4.29 million population (range 1.63-10.72 million population). The median number of paediatric cardiology fellows per training programme was 4 (range 1-17), and duration of training was 3 years (range 2-5 years). An exit examination in paediatric cardiology was conducted in 16 countries (53%) and certification provided by 20 countries (67%). Paediatric cardiologist number is affected by gross domestic product (R2 = 0.41). CONCLUSION: Training varies markedly across European countries. Although formal fellowship programmes exist in many countries, several countries have informal training or no training. Only a minority of countries provide both exit examination and certification. Harmonisation of training and standardisation of exit examination and certification could reduce variation in training thereby promoting high-quality care by European congenital cardiologists.


Assuntos
Cardiologia , Humanos , Adulto , Criança , Cardiologia/educação , Certificação , Currículo , Bolsas de Estudo , Europa (Continente)
13.
Cardiol Young ; 32(2): 185-197, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33843546

RESUMO

Despite enormous strides in our field with respect to patient care, there has been surprisingly limited dialogue on how to train and educate the next generation of congenital cardiologists. This paper reviews the current status of training and evolving developments in medical education pertinent to congenital cardiology. The adoption of competency-based medical education has been lauded as a robust framework for contemporary medical education over the last two decades. However, inconsistencies in frameworks across different jurisdictions remain, and bridging gaps between competency frameworks and clinical practice has proved challenging. Entrustable professional activities have been proposed as a solution, but integration of such activities into busy clinical cardiology practices will present its own challenges. Consequently, this pivot towards a more structured approach to medical education necessitates the widespread availability of appropriately trained medical educationalists, a development that will better inform curriculum development, instructional design, and assessment. Differentiation between superficial and deep learning, the vital role of rich formative feedback and coaching, should guide our trainees to become self-regulated learners, capable of critical reasoning yet retaining an awareness of uncertainty and ambiguity. Furthermore, disruptive innovations such as "technology enhanced learning" may be leveraged to improve education, especially for trainees from low- and middle-income countries. Each of these initiatives will require resources, widespread advocacy and raised awareness, and publication of supporting data, and so it is especially gratifying that Cardiology in the Young has fostered a progressive approach, agreeing to publish one or two articles in each journal issue in this domain.


Assuntos
COVID-19 , Cardiologistas , Cardiologia , Educação Médica , Cardiologia/educação , Currículo , Humanos , SARS-CoV-2
14.
Front Pediatr ; 9: 729198, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34631625

RESUMO

Background: Estrogen receptors (ERs) relate to cardio-protection in adults, but their role in younger patients is not known. We aimed to assess the myocardial expression of ERα- and ERß- mRNA in young patients with congenital cardiac disease and to analyze their putative protective role. Patients and Methods: Twenty children and young adults (seven females and 13 males) with a median age of 13.8 years (interquartile range: 12.3 years) were enrolled in this prospective study. The myocardial expression of ER-mRNA and genes involved in inflammation, growth, and stress response was assessed by real-time PCR and was correlated to post-operative (po) outcome. Results: ER-mRNA was detected in the myocardium of all patients, independently of gender and age. The expression of ER-mRNA correlated with that of mRNA coding for brain natriuretic peptide and for all cytokines tested. A higher ERα-mRNA expression correlated with lower troponin T concentrations at 24 h po (p = 0.032), higher PaO2/FiO2 ratio at 4 h po (p = 0.059), lower fluid retention at 4 h po (p = 0.048), and lower aspartate aminotransferase (AST) levels at 24 h po (p = 0.047). A higher ERß-mRNA expression was also correlated with lower fluid retention at 24 h po (p = 0.048). Patients in whom the levels of ERα- and ERß-mRNA were >P50 had lower troponin T (p = 0.003, respectively) and lower AST concentrations at 24 h po (p = 0.043, respectively) than the others. Conclusions: The expression of ERα- and ERß-mRNA is present in the myocardium of children and young adults with congenital cardiac defect and is associated with lower markers of po organ damage. This suggests that ERs may provide perioperative organ protection in this population.

15.
Tissue Eng Part C Methods ; 27(4): 233-241, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33544046

RESUMO

Pulmonary valve replacement is performed with excellent resultant hemodynamics in patients that have underlying congenital or acquired heart valve defects. Despite recent advancements in right ventricular outflow tract reconstruction, an increased risk of developing infective endocarditis remains, which has a more common occurrence for conduits of bovine jugular vein (BJV) origin compared with cryopreserved homografts. The reason for this is unclear although it is hypothesized to be associated with an aberrant phenotypic state of cells that reendothelialize the graft tissue postimplantation. The aim of this study was to develop an in vitro model that enables the analysis of endothelial cell (EC) attachment to cardiac graft tissues under flow. In the experiments, EC attachment was optimized on bovine pericardium (BP) patch using human umbilical vein ECs. Different biological coatings, namely gelatin, fibronectin, plasma, or a combination of fibronectin and plasma were tested. After cell adaptation, graft tissues were exposed to laminar flow in a parallel-plate flow chamber. Cell retention to the tissue was analyzed after nuclear staining with YO-PRO-1 and a membranous localization of VE-cadherin. Experiments showed that combined coating with fibronectin and blood plasma together with a two-phased shear pattern resulted in a relevant cell monolayer on BP patch and cryopreserved homograft. For BJV tissue, no adherent cells under both static and shear conditions were initially observed. In conclusion, having established the new flow chamber system we could obtain EC layers on the surface of BP patch and cryopreserved pulmonary homograft tissues. The presented in vitro system can serve as a competent model to study cell phenotypes on cardiac grafts in the close-to-physiologic environment. Moreover, this approach allows broad applications and enables further development by testing more complex conditions.


Assuntos
Transplante de Coração , Animais , Bovinos , Criopreservação , Ventrículos do Coração , Humanos , Veias Jugulares , Doadores de Tecidos
16.
Cardiol Young ; 31(3): 344-351, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33407975

RESUMO

The COVID-19 pandemic has had a huge influence in almost all areas of life, affecting societies, economics, and health care systems worldwide. The paediatric cardiology community is no exception. As the challenging battle with COVID-19 continues, professionals from the Association for the European Paediatric and Congenital Cardiology receive many questions regarding COVID-19 in a Paediatric and Congenital Cardiology setting. The aim of this paper is to present the AEPC position on frequently asked questions based on the most recent scientific data, as well as to frame a discussion on how to take care of our patients during this unprecedented crisis. As the times are changing quickly and information regarding COVID-19 is very dynamic, continuous collection of evidence will help guide constructive decision-making.


Assuntos
Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Antivirais/uso terapêutico , Arritmias Cardíacas/tratamento farmacológico , Tratamento Farmacológico da COVID-19 , Cardiopatias Congênitas/terapia , Fatores Imunológicos/uso terapêutico , Monofosfato de Adenosina/análogos & derivados , Monofosfato de Adenosina/uso terapêutico , Alanina/análogos & derivados , Alanina/uso terapêutico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Síndrome de Brugada/tratamento farmacológico , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/fisiopatologia , COVID-19/epidemiologia , COVID-19/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Cardiologia , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/fisiopatologia , Transplante de Coração , Humanos , Transmissão Vertical de Doenças Infecciosas , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/epidemiologia , Síndrome do QT Longo/fisiopatologia , Miocardite/epidemiologia , Miocardite/fisiopatologia , Miocárdio , Pediatria , Medição de Risco , SARS-CoV-2 , Sociedades Médicas , Síndrome de Resposta Inflamatória Sistêmica/tratamento farmacológico , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/fisiopatologia
17.
J Thorac Cardiovasc Surg ; 161(6): e457-e472, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-31926702

RESUMO

OBJECTIVE: Although recent advances in pulmonary valve replacement have enabled excellent hemodynamics, infective endocarditis remains a serious complication, particularly for implanted bovine jugular vein (BJV) conduits. METHODS: We investigated contributions by platelets and plasma fibrinogen to endocarditis initiation on various grafts used for valve replacement. Thus, adherence of Staphylococcus aureus and platelets to 5 graft tissues was studied quantitatively in perfusion chambers, assisted by microscopic analysis. We also evaluated standard antiplatelet therapy to prevent onset of S aureus endocarditis. RESULTS: Of all tissues, bovine pericardium (BP) showed the greatest fibrinogen binding. Perfusion of all plasma-precoated tissues identified BP and BJVwall with the greatest affinity for S aureus. Perfusions of anticoagulated human blood over all tissues also triggered more platelet adhesion to BP and BJVwall as single platelets. Several controls confirmed that both S aureus and platelets were recruited on immobilized fibrinogen. In addition, perfusions (and controls) over plasma-coated tissues with whole blood, spiked with S aureus, revealed that bacteria exclusively bound to adhered platelets. Both the platelet adhesion and platelet-mediated S aureus recruitment required platelet αIIbß3 and coated or soluble fibrinogen, respectively, interactions abrogated by the αIIbß3-antagonist eptifibatide. Also, standard antiplatelet therapy (aspirin/ticagrelor) reduced the adherence of S aureus in blood to BJV 3-fold. CONCLUSIONS: Binding of plasma fibrinogen to especially BJV grafts enables adhesion of single platelets via αIIbß3. S aureus then attaches from blood to (activated) bound platelet αIIbß3 via plasma fibrinogen. Dual antiplatelet therapy appears a realistic approach to prevent endocarditis and its associated mortality.


Assuntos
Bioprótese , Endocardite Bacteriana , Valvas Cardíacas , Inibidores da Agregação Plaquetária , Infecções Estafilocócicas , Animais , Aderência Bacteriana , Plaquetas/fisiologia , Bovinos , Fibrinogênio , Valvas Cardíacas/microbiologia , Valvas Cardíacas/fisiopatologia , Ligação Proteica , Staphylococcus aureus
18.
JTCVS Open ; 8: 301-312, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36004157

RESUMO

Objective: Antiaggregants (Ag) could prevent infective endocarditis (IE) in preclinical studies. In this study we investigated whether Ag or anticoagulants (Ac) were also protective in humans. Methods: In part I we determined the incidence of IE of bioprosthetic aortic valves (PVE) in 333 consecutive patients who underwent aortic valve replacement for noninfective aortic insufficiency between 2009 and 2019. In part II we retrospectively analyzed data of 137 patients who had developed IE of the native aortic valve (NVE) between 2007 and 2015. Multivariable Fine-Gray and logistic regression models were used to investigate associations between Ag and Ac therapy and IE. Results: Sixteen of 333 (4.8%) aortic valve replacement recipients developed PVE after a median of 3.72 years. There was no association between Ag and PVE, whereas Ac was associated with a higher IE occurrence (no association for vitamin K antagonists but significant for fondaparinux or low molecular-weight heparins; hazard ratio, 4.61; 95% CI, 1.01-21.9). In contrast, among the 137 patients in part II, vitamin K antagonists (odds ratio [OR], 7.52; 95% CI, 2.51-22.6), double antiplatelet therapy (OR, 44.3; 95% CI, 4.83-407), novel oral Ac (OR, 4.17; 95% CI, 1.15-15.1), and fondaparinux or low molecular-weight heparins (OR, 9.87; 95% CI, 1.81-53.9), but not acetylsalicylic acid, were associated with NVE. Conclusions: Ac were associated with IE in both cohorts, whereas Ag were not associated with PVE. This might reflect differences in the studied populations, with Ag and Ac being prescribed for conditions associated with long-term IE risk in the NVE cohort. Therefore, determining the potential protective effect of Ag and Ac will necessitate further well-controlled studies.

19.
Cardiol Young ; 30(11): 1572-1587, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33109300

RESUMO

The recommendations of the Association for European Paediatric and Congenital Cardiology for basic training in paediatric and congenital cardiology required to be recognised as a paediatric cardiologist by the Association for European Paediatric and Congenital Cardiology are described below. Those wishing to achieve more advanced training in particular areas of paediatric cardiology should consult the training recommendations of the different Association for European Paediatric and Congenital Cardiology Working Groups available on the Association for European Paediatric and Congenital Cardiology website (www.aepc.org) and the respective publications 1-6. The development of training requirements is the responsibility of the Educational Committee and the Association for European Paediatric and Congenital Cardiology Council in collaboration with the Working Groups of the Association for European Paediatric and Congenital Cardiology. Trainees should be exposed to all aspects of general paediatric and congenital cardiology from fetal life to adolescence and adulthood. Centres performing generalised and specialised work in paediatric and congenital cardiology should be committed to deliver postgraduate training. At each training institute, trainers should be appointed to supervise and act as mentors to the trainees. Association for European Paediatric and Congenital Cardiology will provide basic teaching courses to supplement the training process.


Assuntos
Cardiologia , Cardiopatias Congênitas , Adolescente , Adulto , Criança , Humanos
20.
Cardiol Young ; 30(12): 1783-1787, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32951625

RESUMO

OBJECTIVE: Infective endocarditis remains a severe complication associated with a high morbidity and mortality in patients after heart valve replacement. Exploration of the pathogenesis is of high demand and we, therefore, present a competent model that allows studying bacterial adherence and the role of plasma fibrinogen in this process using a new in-house designed low-volume flow chamber. Three cardiac graft tissues used for pulmonary valve replacement have been tested under shear conditions to investigate the impact of surface composition on the adhesion events. METHODS: Tissue pieces of cryopreserved homograft (non-decellularised), decellularised homograft and bovine pericardium patch were investigated for fibrinogen binding. Adherence of Staphylococcus aureus to these graft tissues was studied quantitatively under flow conditions in our newly fabricated chamber based on a parallel plates' modality. The method of counting colony-forming units was reliable and reproducible to assess the propensity of different graft materials for bacterial attachment under shear. RESULTS: Bacterial perfusions over all plasma-precoated tissues identified cryopreserved homograft with the lowest affinity for S. aureus compared to decellularised homograft presenting a significantly higher bacterial adhesion (p < 0.05), which was linked to a more avid fibrinogen binding (p < 0.01). Bovine pericardial patch, as a reference tissue in this study, was confirmed to be the most susceptible tissue graft for the bacterial adhesion, which was in line with our previous work. CONCLUSION: The two studied homograft tissues showed different levels of bacterial attachment, which might be postulated by the involvement of fibrinogen in the adhesion mechanism(s) shown previously for bovine tissues.


Assuntos
Endocardite Bacteriana , Transplante de Coração , Aloenxertos , Animais , Bovinos , Endocardite Bacteriana/cirurgia , Fibrinogênio , Humanos , Staphylococcus aureus , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA